A modular high voltage stackable battery storage system for small commercial and industrial sites. 16.08 kWh modules stack cable-free into clusters of 64.31–241.15 kWh, and up to four clusters run in parallel for 964.8 kWh — with cell-level active balancing across the whole tower.
11000 cycles @25°C, 0.5P · 95% depth of discharge · Floor-standing, stackable
Every capability on this page is taken from the EnerTower-HA16 datasheet — the same numbers your technical team will verify.
Modules connect directly module-to-module without cabling between them. One technician stacks a tower; Column A holds 4–7 modules, Column B up to 8.
Active balancing across the whole cluster guarantees long-term cell consistency, minimizes cell voltage drift and slows degradation over 11000 cycles.
Built-in suppression releases in 3 seconds at a 130°C trigger — faster release with a lower trigger temperature than conventional solutions.
Custom electrolyte and a high-temperature ceramic separator support 11000 cycles @25°±2°C at 0.5P with 95% depth of discharge.
CAN / RS485 communication ports as standard, optional WiFi module for remote operation and maintenance — with a 3-second fast response.
IP65 protection (optional IP20), C3 anti-corrosion grade, −20°C to 55°C discharge range and an optional heater version for charging below 0°C.

Column A and Column B towers share the same 770 × 435 mm footprint and the same 16.08 kWh module, so capacity scales by module count, not by redesign.

| Battery type | LiFePO4, cobalt-free |
|---|---|
| Combination mode | 4–15 modules in series, (16S)S–(16S)15S |
| Nominal voltage | 204.8 – 768.0 V |
| Nominal capacity | 314 Ah |
| Nominal energy | 64.31 – 241.15 kWh per cluster |
| Operating voltage | 182.4 – 852.0 V |
| Recommended / max continuous current | 157 A / 157 A |
| Dimensions (W×D×H) | Column A: 770 × 435 × (250+248×N) mm, 4≤N≤7 Column B: 770 × 435 × (200+248×N) mm, 1≤N≤8 |
| Weight | Column A: 33+118×N kg · Column B: 16+118×N kg |
| Capacity expansion | Up to 4 clusters in parallel (max 964.8 kWh) |

| Battery type | LiFePO4 |
|---|---|
| Combination mode | 1P16S |
| Nominal voltage | 51.2 V |
| Nominal capacity | 314 Ah |
| Nominal energy | 16.08 kWh |
| Operating voltage | 43.2–58.4 V (T≥0°C); 38.4–58.4 V (T<0°C) |
| Recommended / max continuous current | 157 A / 157 A |
| Dimensions (W×D×H) | 770 × 435 × 248 mm |
| Weight | 118 + 2 kg |
Source: EnerTower-HA16 official datasheet. Capacity expands to 964.8 kWh with up to 4 clusters in parallel.
Modules lock together mechanically and connect electrically through integrated wireless-style connectors on top of each unit — no torque specs, no loom, no two-person lift.

| System parameter | Value |
|---|---|
| Battery type | LiFePO4, cobalt-free |
| Combination mode | 4–15 modules in series, (16S)S–(16S)15S |
| Nominal voltage | 204.8 – 768.0 V |
| Nominal capacity | 314 Ah |
| Nominal energy | 64.31 – 241.15 kWh per cluster |
| Operating voltage | 182.4 – 852.0 V |
| Recommended / max continuous current | 157 A / 157 A |
| Depth of discharge | 95% |
| Cycle life | 11000 cycles @25°±2°C, 0.5P |
| DC efficiency | 94% |
| Cooling method | Natural cooling |
| Communication | CAN / RS485 |
| Installation | Floor-standing, stackable |
| Protection level | IP65, optional IP20 |
| Anti-corrosion grade | C3 (default) |
| Max. operating altitude | 3000 m (derating above 2000 m) |
| Charging temperature | 0–55°C / −20–55°C optional heater version |
| Discharging temperature | −20–55°C |
| Storage temperature | −20–40°C |
| Humidity range | 10%–90% RH, non-condensing |
| Fire safety | Nano Solid Novec1230 (3 s response, 130°C trigger) |
| Remote monitoring | Optional WiFi module, remote O&M |
| Compatible inverters | Solis, Deye, Growatt, Solinteg, Megarevo |
| Certification | IEC 62619, CE, UN38.3 |
Source: EnerTower-HA16 official datasheet. Column A / Column B tower dimensions and weights are listed in the datasheet block above; capacity expands to 964.8 kWh with up to 4 clusters in parallel.
Pick the model that matches the load: 4 to 15 modules configure a single cluster from 64.31 kWh to 241.15 kWh, and up to 4 clusters run in parallel.
| Modules | Model | Rated energy | Nominal voltage |
|---|---|---|---|
| 4 | ESS-204.8/314 | 64.31 kWh | 204.8 V |
| 5 | ESS-256/314 | 80.38 kWh | 256.0 V |
| 6 | ESS-307.2/314 | 96.46 kWh | 307.2 V |
| 7 | ESS-358.4/314 | 112.54 kWh | 358.4 V |
| 8 | ESS-409.6/314 | 128.61 kWh | 409.6 V |
| 9 (4+5) | ESS-460.8/314 | 144.69 kWh | 460.8 V |
| 10 (5+5) | ESS-512/314 | 160.77 kWh | 512.0 V |
| 11 (5+6) | ESS-563.2/314 | 176.84 kWh | 563.2 V |
| 12 (6+6) | ESS-614.4/314 | 192.92 kWh | 614.4 V |
| 13 (6+7) | ESS-665.6/314 | 209.00 kWh | 665.6 V |
| 14 (7+7) | ESS-716.8/314 | 225.08 kWh | 716.8 V |
| 15 (7+8) | ESS-768/314 | 241.15 kWh | 768.0 V |
Parallel expansion: 2 clusters → 482.3 kWh, 3 clusters → 723.45 kWh, 4 clusters → 964.8 kWh.

Because expansion is additive — more modules per tower, more towers per bank — you can commission at the load you have today and add clusters without replacing the BMS or re-engineering the room.
Confirmed per the official datasheet. Send us the inverter model and required capacity — our engineers verify the voltage window and recommend the right module count before you order.
Need a brand that is not listed? Ask for the current compatibility list →
A modular energy storage solution for small commercial facilities, industrial sites and distributed energy storage projects.
Retail, offices and cold chain: shave demand peaks and back up critical loads with 64–241 kWh per bank.
IP65, C3 anti-corrosion and −20°C discharge tolerate dusty, unheated plant rooms and semi-outdoor installations.
Stack banks across multiple buildings or sites and scale each one independently from 64 kWh toward 964.8 kWh.
Pair with PV and a compatible hybrid inverter to store midday surplus for evening tariff windows.
3 s fast response keeps operations running through grid events without generator start delays.
Buffer charging points on constrained connections; 157 A continuous current per cluster supports DC charging loads.
Natural cooling, wide temperature windows and built-in fire suppression — the EnerTower-HA16 keeps running in plant rooms and outdoor enclosures without extra HVAC.
Innovative custom electrolyte and a high-temperature ceramic separator slow capacity fade across the whole cluster.
Send the site requirements and our engineers will return a module count, cluster layout and inverter match — typically within one business day.
Prefer email? Write to info@enershare.cn